Objective

The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor for wide-neck bifurcation aneurysms, avoiding adjunctive stents or dual antiplatelet therapy. Evidence in ruptured cases remains limited. We evaluated 1-year angiographic and clinical outcomes of ruptured aneurysms treated with the WEB device.

Methods

Thirteen patients with aneurysmal subarachnoid hemorrhage treated between January 2023 and December 2024 were retrospectively analyzed. Hunt-Hess grade, modified Fisher grade, and 12-month modified Rankin Scale (mRS) scores were reviewed. Follow-up included 6-month magnetic resonance angiography and 12-month digital subtraction angiography (DSA). Occlusion was classified via the WEB Occlusion Scale (WOS), with adequate occlusion defined as WOS A or B.

Results

The cohort comprised 11 males and two females (mean age, 49.4 years; range, 41-82). Hunt-Hess grades were II in 69% (9/13), IV in 23% (3/13), and V in 8% (1/13). Modified Fisher grades were 3 in 38% (5/13) and 4 in 62% (8/13). At 12-month DSA, adequate occlusion was achieved in 69% (9/13; WOS A: n=3, WOS B: n=6). Neck remnants occurred in three aneurysms (23%), and one aneurysm remnant (8%) required stent-assisted coiling. Twelve-month mRS scores were 0 in nine patients (69%), 3 in two (15%), and 4 in two (15%). No complications, rebleeding, or deaths occurred.

Conclusion

Primary WEB embolization of ruptured aneurysms achieved favorable 1-year occlusion without rebleeding, demonstrating feasibility when avoiding stents and antiplatelet therapy is desirable.

INTRODUCTION

Endovascular treatment is recognized as the first therapeutic option for ruptured and unruptured intracranial aneurysms [1]. Endovascular treatment of wide-neck bifurcation aneurysms is technically challenging, and these aneurysms are associated with a higher rate of recanalization [2]. Bridging-neck devices such as stents require dual-antiplatelet therapy and are associated with a higher rate of complications; in ruptured aneurysms, this anti-aggregation regimen carries an inherent risk of early rebleeding and hemorrhagic complications in the perioperative period [3-5]. Despite anti-aggregation, thromboembolic complications still occur [6,7].
The Woven EndoBridge (WEB; MicroVention) is an intrasaccular flow disruptor developed primarily for the endovascular treatment of wide-neck bifurcation aneurysms, without the need for adjunctive stents or dual antiplatelet therapy. The first clinical results of the WEB device demonstrated good safety and efficacy [8]. However, published data on WEB treatment of ruptured aneurysms remain limited, and follow-up in most series does not extend beyond 1 year on average [9,10]. A single-center series of 100 ruptured aneurysms treated primarily with the WEB has been reported, with favorable long-term results [11,12].
In this study, we report the 1-year angiographic and clinical follow-up of a consecutive single-center cohort of ruptured intracranial aneurysms treated with the WEB device as primary treatment.

MATERIALS AND METHODS

Study design and population

This retrospective observational study analyzed a prospectively maintained institutional database and was conducted in accordance with our institutional privacy policy; institutional review board approval (Hallym University Dongtan Sacred Heart Hospital, No. HDT-2023-11-008) and the requirement for informed consent were handled per institutional policy. From January 2023 through December 2024, 122 cases of ruptured intracranial aneurysms were treated at our center: 14 by surgical clipping, 76 by conventional coil embolization, 19 by stent-assisted coil embolization, and 13 by the WEB device. All 13 consecutive WEB-treated patients constituted the final analytic cohort (Fig. 1).

Woven EndoBridge device

The WEB is a self-expanding, retrievable, electrothermally detachable, nitinol braided device placed within the aneurysm sac. Current single-layer iterations are available as a barrel-shaped WEB Single-Layer (SL) and a spherical WEB Single-Layer Sphere, with enhanced-visualization variants incorporating composite nitinol-platinum wire strands. Once deployed, the WEB modifies blood flow at the aneurysm neck and induces intra-aneurysmal thrombosis. The device can be fully retrieved until final electrothermal detachment. In this cohort, all aneurysms were treated with a WEB SL device; device sizes ranged from 4.0×2 mm to 10×6 mm (Table 1). Device width was selected 1-2 mm larger than the maximal aneurysm width, and device height was selected approximately 1 mm shorter than the measured aneurysm height.

Indications and treatment

Treatment modality and technique were determined by multidisciplinary discussion, and ruptured aneurysms were treated acutely after admission. The WEB was favored for aneurysms suitable for intrasaccular flow disruption when avoidance of an adjunctive stent and dual antiplatelet therapy was desirable. With the patient under general anesthesia and via a transfemoral approach, a microcatheter was navigated into the aneurysm through a coaxial system with an intermediate catheter. An intravenous bolus of 3,000 IU unfractionated heparin was administered at the start of the procedure. Because all procedures lasted less than 60 minutes, no additional heparin was administered; activated clotting time was not routinely measured. After WEB implantation, aspirin 100 mg once daily was prescribed for 2 weeks; dual antiplatelet therapy was not used. In one patient (No. 12), adjunctive coiling was performed in addition to the WEB.

Data collection and follow-up

Patient demographics, baseline Hunt-Hess and modified Fisher grades, aneurysm characteristics (maximal dome width, height/depth, and neck width), treatment details, procedure-related complications, rebleeding, retreatment, mortality, and 12-month modified Rankin Scale (mRS) scores were collected. All patients underwent magnetic resonance angiography (MRA) at 6 months for interval surveillance and catheter digital subtraction angiography (DSA) at 12 months for the primary angiographic endpoint. Twelve-month DSA was interpreted by two experienced neurointerventionists. Occlusion was graded using the WEB Occlusion Scale (WOS): complete occlusion (WOS A), complete occlusion with residual opacification of the proximal recess of the device (complete occlusion with proximal-recess residual; WOS B), neck remnant (WOS C), and aneurysm remnant (WOS D). Adequate occlusion was defined as WOS A or B. A favorable clinical outcome was defined as an mRS score of 0-2.

Statistical analysis

Quantitative variables were expressed as means and medians with ranges; qualitative variables were expressed as frequencies and percentages. Given the small sample size, analyses were descriptive.

RESULTS

Population

From January 2023 through December 2024, 13 of 122 ruptured intracranial aneurysm cases were treated with the WEB device and included in this analysis. There were 11 males and two females, with a mean age of 49.4 years (median, 44 years; range, 41-82 years). All 13 patients presented with subarachnoid hemorrhage. Hunt-Hess grades were II in nine patients (69%), IV in three (23%), and V in one (8%); modified Fisher grades were 3 in five patients (38%) and 4 in eight (62%) (Table 2). Aneurysm locations were the anterior communicating artery in six patients (46%), the middle cerebral artery bifurcation in three (23%), and the basilar tip in four (31%).
The mean maximal aneurysm diameter was 6.3 mm (median, 5.5 mm; range, 3.6-10.3 mm), and the mean neck width was 3.9 mm (median, 3.4 mm; range, 2.6-7.3 mm). Seven aneurysms (54%) met the definition of a wide neck. All aneurysms were treated with a WEB SL device, with sizes ranging from 4.0×2 mm to 10×6 mm. One patient (No. 12) underwent adjunctive coiling in addition to the WEB (Table 1).

Follow-up

All 13 patients completed the scheduled 6-month MRA and 12-month DSA examinations. Twelve-month clinical follow-up and mRS scores were also available for all patients.

Morbidity and mortality

There were no procedure-related complications, post-treatment thromboembolic events, rebleeding, or deaths during follow-up. At 12 months, mRS scores were 0 in nine patients (69%), 3 in two (15%), and 4 in two (15%). A favorable outcome (mRS 0-2) was observed in nine of 13 patients (69%) (Table 2).

Aneurysm occlusion and retreatment

At 12-month DSA (Table 1), nine of 13 aneurysms (69%) demonstrated adequate occlusion: three (23%) were completely occluded (WOS A) and six (46%) showed complete occlusion with residual opacification limited to the proximal recess of the device (WOS B). Representative cases are shown in Fig. 2 and 3. A neck remnant (WOS C) was present in three aneurysms (23%), and an aneurysm remnant (WOS D) was present in one aneurysm (8%). The single aneurysm remnant occurred in a wide-neck anterior communicating artery aneurysm (No. 7; dome, 8.5 mm; neck, 5.0 mm) and was identified on the 12-month DSA. Stent-assisted coil embolization was performed 2 weeks later (Fig. 4).

DISCUSSION

This single-center study demonstrates that primary treatment of ruptured intracranial aneurysms with the WEB device is feasible, with adequate angiographic occlusion (WOS A+B) achieved in 69% of aneurysms at 12-month DSA and no rebleeding during follow-up. A neck remnant was observed in 23% and an aneurysm remnant in 8%. At 12 months, 69% of patients had a favorable clinical outcome (mRS 0-2), and no patient died. More than half of the treated aneurysms (54%) had a wide neck, reflecting the primary indication for the device.
Prevention of rebleeding is the primary goal in the treatment of ruptured aneurysms. In our cohort, there were no rebleeds during follow-up, consistent with prior WEB series in the ruptured setting [9,10] and comparable to reported rates after coiling [13,14]. Patients received aspirin monotherapy at 100 mg daily for only 2 weeks after WEB implantation, and no dual antiplatelet therapy was used. This short antiplatelet regimen is an important advantage compared with stent-assisted coiling in the acute phase of subarachnoid hemorrhage, in which dual antiplatelet therapy may increase hemorrhagic risk [3-5,7]. Two meta-analyses of stent-assisted coiling for ruptured wide-neck aneurysms reported total complication rates of approximately 20% [6,15].
Residual opacification limited to the proximal recess of the device (WOS B) was the most common finding in our cohort. This appearance is frequently observed after WEB implantation and is related to the well-described phenomenon of “WEB shape modification,” a decrease in device height due to deepening of the central recess, probably from compression [16,17]. Such residuals and small neck remnants are generally expected to remain stable and often do not require retreatment; nevertheless, the clinical significance of neck remnants remains debated, because remnants after aneurysm treatment carry an inherent risk of re-rupture, as demonstrated for coiling [18]. In our series, the four aneurysms with a neck or aneurysm remnant tended to have larger dimensions and wider necks, in keeping with the recognized association between aneurysm and neck size and incomplete occlusion; continued angiographic surveillance of these aneurysms is therefore warranted.
Our findings are consistent with the larger single-center experience of van Rooij et al. [11] and Kortman et al. [12], in which primary WEB treatment of 100 ruptured aneurysms produced stable occlusion with a low retreatment rate and no rebleeds on long-term follow-up. The present cohort adds 1-year data from an independent single-center series and supports the WEB as a valuable alternative to coils and to stent-assisted coiling for ruptured wide- and small-neck aneurysms.

Limitations

This study is limited by its single-center, uncontrolled, retrospective design and small sample size (n=13), which preclude robust statistical inference and increase the possibility of selection bias. Angiographic results were assessed at the treating center without independent core-laboratory adjudication. Although all patients underwent 6-month MRA and 12-month DSA, follow-up beyond 1 year was not available; longer-term surveillance is required to confirm the durability of occlusion.

CONCLUSION

In this single-center cohort, primary WEB treatment of ruptured intracranial aneurysms was feasible and achieved adequate occlusion in the majority of aneurysms at 1 year without rebleeding. The WEB may offer an alternative to conventional and stent-assisted coiling without the need for an adjunctive stent or dual antiplatelet therapy; only short-term aspirin monotherapy was used in this cohort. Larger series with longer follow-up are needed to confirm these findings.

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

Fig. 1.
Patient selection flow diagram. The 13 patients treated with the Woven EndoBridge (WEB) device constituted the final analytic cohort.
nf-2026-00262f1.jpg
Fig. 2.
(A) Pretreatment digital subtraction angiography (DSA) demonstrating the aneurysm. (B) Post-deployment image showing the Woven EndoBridge (WEB) device in place. (C) Twelve-month follow-up DSA demonstrating complete occlusion of the aneurysm (WEB Occlusion Scale A) with preservation of the parent and branch vessels.
nf-2026-00262f2.jpg
Fig. 3.
(A) Pretreatment digital subtraction angiography (DSA) in the working projection demonstrating the aneurysm. (B) Immediate post-deployment image showing the Woven EndoBridge (WEB) device positioned within the aneurysm sac. (C) Twelve-month follow-up DSA showing complete occlusion of the aneurysm with residual opacification confined to the proximal recess of the device (WEB Occlusion Scale B) and a patent parent artery.
nf-2026-00262f3.jpg
Fig. 4.
(A) Pretreatment digital subtraction angiography (DSA) showing the wide-neck aneurysm. (B) Post-deployment image with the Woven EndoBridge (WEB) device within the sac. (C) Follow-up DSA demonstrating an aneurysm remnant with contrast filling of the sac (WEB Occlusion Scale D). (D) Retreatment with stent-assisted coiling, with subsequent angiographic occlusion of the aneurysm and no procedure-related complication.
nf-2026-00262f4.jpg
Table 1.
Aneurysm, device, and 12-month angiographic characteristics (n=13)
No. Location Dome*/height (mm)† Neck (mm)‡ WEB SL size (mm) WOS 12-month DSA result
1 Rt. MCA bif 5.0/3.3 4.8 5×2 C NR
2 MCA bif 3.6/3.3 2.9 4.0×2 B COr
3 AcomA 8.3/6.1 5.6 8×3 B COr
4 AcomA 4.9/3.7 2.6 5×3 A CO
5 AcomA 5.6/5.6 3.4 6×3 C NR
6 Basilar tip 5.5/4.5 3.6 5.0×3 B COr
7 AcomA 8.5/6.5 5.0 6.0×4 D AR
8 AcomA 4.9/5.5 2.9 6.0×3 B COr
9 MCA bif 5.3/4.2 2.6 5.0×3 A CO
10 Basilar tip 5.4/5.6 4.1 5×2 B COr
11 Basilar tip 10.1/8.7 7.3 10×6 C NR
12 AcomA 8.2/10.3 3.0 6×3+coil B COr
13 Basilar tip 4.0/3.8 3.4 4.5×3 A CO

Sex: 11 males and 2 females. Age: mean, 49.4 years; median, 44 years (range, 41-82 years). Hunt-Hess grade: II, 9 (69%); IV, 3 (23%); V, 1 (8%). Modified Fisher grade: 3, 5 (38%); 4, 8 (62%). Twelve-month modified Rankin Scale (mRS): 0, 9 (69%); 3, 2 (15%); 4, 2 (15%); favorable outcome (mRS 0-2), 9 (69%). No procedure-related complications, rebleeding, or deaths occurred. Location: AcomA, 6 (46%); MCA bifurcation, 3 (23%); basilar tip, 4 (31%). Twelve-month WOS: A, 3 (23%); B, 6 (46%); C, 3 (23%); D, 1 (8%); adequate occlusion (A+B), 9 (69%). WEB: Woven EndoBridge, SL: Single-Layer, WOS: WEB Occlusion Scale, DSA: digital subtraction angiography, Rt.: right, MCA: middle cerebral artery, bif: bifurcation, AcomA: anterior communicating artery, NR: neck remnant, COr: complete occlusion with proximal-recess residual, CO: complete occlusion, AR: aneurysm remnant. *Dome: maximal dome width†Height: depth/length.‡Wide neck: neck≥4 mm or dome-to-neck ratio≤1.5.

Table 2.
Baseline clinical characteristics and 12-month clinical outcomes (n=13)
No. Sex Age (yr) Hunt-Hess grade Modified Fisher grade 12-month mRS
1 Male 42 II 4 0
2 Female 43 II 4 0
3 Male 82 IV 4 4
4 Male 47 II 4 0
5 Male 42 II 3 0
6 Female 57 IV 4 0
7 Male 41 II 3 0
8 Male 64 II 3 3
9 Male 43 II 4 0
10 Male 44 IV 4 3
11 Male 51 II 4 0
12 Male 44 V 3 4
13 Male 42 II 3 0

mRS: modified Rankin Scale.

REFERENCES

1. Cognard C, Pierot L, Anxionnat R, Ricolfi F; Clarity Study Group. Results of embolization used as the first treatment choice in a consecutive nonselected population of ruptured aneurysms: clinical results of the Clarity GDC study. Neurosurgery 2011;69:837-42
crossref pmid pdf
2. Pierot L, Cognard C, Anxionnat R, Ricolfi F; CLARITY Investigators. Endovascular treatment of ruptured intracranial aneurysms: factors affecting midterm quality anatomic results: analysis in a prospective, multicenter series of patients (CLARITY). AJNR Am J Neuroradiol 2012;33:1475-80
crossref pmid pmc
3. Chalouhi N, Jabbour P, Singhal S, Drueding R, Starke RM, Dalyai RT, et al. Stent-assisted coiling of intracranial aneurysms: predictors of complications, recanalization, and outcome in 508 cases. Stroke 2013;44:1348-53
crossref pmid
4. Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, et al. Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 2010;41:110-5
crossref pmid
5. Chung J, Lim YC, Suh SH, Shim YS, Kim YB, Joo JY, et al. Stent-assisted coil embolization of ruptured wide-necked aneurysms in the acute period: incidence of and risk factors for periprocedural complications. J Neurosurg 2014;121:4-11
crossref pmid
6. Bsat S, Bsat A, Tamim H, Chanbour H, Alomari SO, Houshiemy MNE, et al. Safety of stent-assisted coiling for the treatment of wide-necked ruptured aneurysm: a systematic literature review and meta-analysis of prevalence. Interv Neuroradiol 2020;26:547-56
crossref pmid pmc pdf
7. Bechan RS, Sprengers ME, Majoie CB, Peluso JP, Sluzewski M, van Rooij WJ. Stent-assisted coil embolization of intracranial aneurysms: complications in acutely ruptured versus unruptured aneurysms. AJNR Am J Neuroradiol 2016;37:502-7
crossref pmid
8. Asnafi S, Rouchaud A, Pierot L, Brinjikji W, Murad MH, Kallmes DF. Efficacy and safety of the Woven EndoBridge (WEB) device for the treatment of intracranial aneurysms: a systematic review and meta-analysis. AJNR Am J Neuroradiol 2016;37:2287-92
crossref pmid pmc
9. Essibayi MA, Lanzino G, Brinjikji W. Safety and efficacy of the Woven EndoBridge device for treatment of ruptured intracranial aneurysms: a systematic review and meta-analysis. AJNR Am J Neuroradiol 2021;42:1627-32
crossref pmid pmc
10. Monteiro A, Lazar AL, Waqas M, Rai HH, Baig AA, Cortez GM, et al. Treatment of ruptured intracranial aneurysms with the Woven EndoBridge device: a systematic review. J Neurointerv Surg 2022;14:366-70
crossref pmid
11. van Rooij SBT, van Rooij WJ, Peluso JP, Sluzewski M, Bechan RS, Kortman HG, et al. WEB treatment of ruptured intracranial aneurysms: a single-center cohort of 100 patients. AJNR Am J Neuroradiol 2017;38:2282-7
crossref pmid pmc
12. Kortman H, van Rooij SBT, Mutlu U, Boukrab I, van Rooij WJ, van der Pol B, et al. WEB treatment of ruptured intracranial aneurysms: long-term follow-up of a single-center cohort of 100 patients. AJNR Am J Neuroradiol 2023;44:60-4
crossref pmid
13. Molyneux AJ, Kerr RS, Birks J, Ramzi N, Yarnold J, Sneade M, et al. Risk of recurrent subarachnoid haemorrhage, death, or dependence and standardised mortality ratios after clipping or coiling of an intracranial aneurysm in the International Subarachnoid Aneurysm Trial (ISAT): long-term follow-up. Lancet Neurol 2009;8:427-33
crossref pmid pmc
14. Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, et al. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. J Stroke Cerebrovasc Dis 2002;11:304-14
crossref pmid
15. Zhang X, Zuo Q, Tang H, Xue G, Yang P, Zhao R, et al. Stent assisted coiling versus non-stent assisted coiling for the management of ruptured intracranial aneurysms: a meta-analysis and systematic review. J Neurointerv Surg 2019;11:489-96
crossref pmid
16. Rosskopf J, Braun M, Dreyhaupt J, Beer M, Schmitz BL, Ozpeynirci Y. Shape modification is common in Woven EndoBridge-treated intracranial aneurysms: a longitudinal quantitative analysis study. AJNR Am J Neuroradiol 2020;41:1652-6
crossref pmid pmc
17. Janot K, Herbreteau D, Amelot A, Charbonnier G, Boustia F, Narata AP, et al. Quantitative evaluation of WEB shape modification: a five-year follow-up study. J Neuroradiol 2020;47:193-6
crossref pmid
18. Johnston SC, Dowd CF, Higashida RT, Lawton MT, Duckwiler GR, Gress DR; CARAT Investigators. Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study. Stroke 2008;39:120-5
crossref pmid
TOOLS
METRICS Graph View
  • 0 Crossref
  •  0 Scopus
  • 690 View
  • 18 Download
ORCID iDs

Junghyun Park
https://orcid.org/0000-0002-1187-2918

Related articles


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Neurosurgery, Yonsei University College of Medicine
50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
Tel: +82-2-2228-2150    Fax: +82-2-393-9979    E-mail: changws@yonsei.ac.kr / changws0716@yuhs.ac                

Copyright © 2026 The Korean Society of Stereotactic and Functional Neurosurgery.

Developed in M2PI

Close layer
prev next