Journal of the Korean Society of Stereotactic and Functional Neurosurgery 2014;10(2):65-70.
Published online September 30, 2014.
Electrical Stimulation of the Motor Cortex in the Rat Lithium-Pilocarpine Model of Status Epilepticus
Sang Soo Park, Ji Ha Lee, Hyo Joon Kim
Department of Neurosurgery, Seonam University, College of Medicine, Presbyterian Medical Center, Jeonju, Korea Medical Device Clinical Trial Center, Presbyterian Medical Center, Jeonju, Korea
Abstract
Purpose
The current study was conducted to explore a use of electrical stimulation on a motor cortex in the rat lithium-pilocarpine model of status epilepticus (SE) as a useful method for seizure inhibition.
Methods
An electrode was implanted in the epidural space above the motor cortex of 16 healthy male Sprague-Dawley rats separately. After a surgery, rats received an intraperitoneal injection with lithium and pilocarpine to induce SE. Fourteen rats reaching to over the Racine's scale stage 3 were divided into four groups ; group 1 for anodal pulse stimulation, group 2 for cathodal pulse stimulation, group 3 for biphasic pulse stimulation, and group 4 for direct current (DC) stimulation. Two rats not reaching to the Racine's scale stage 3 were excluded. Electrical stimulation was carried out for 5 minutes at 3-minute interval, or for 6 seconds at 3-second interval in each group. The amplitude of the stimulation varied from half the movement threshold (HMT), to submovement threshold (SMT), to movement threshold (MT), and then to 1.1-1.5 times movement threshold (1.1-1.5MT). Each session was performed at a frequency ranging from 2 to 1,000Hz. During the stimulation, a video recording had been made for observing and grading the seizure activity of rats.
Results
A cathodal pulse with a width of 250's, a frequency of 500Hz and amplitude of 1.5MT successfully inhibited seizure activity. No other stimulation parameters significantly affected seizure activity. Our results suggest that a specific combination of stimulation parameters applied to the motor cortex has inhibitory effects on seizure activity in the rat lithium-pilocarpine model of status epilepticus.
Conclusions
The results of the current study indicate that a sudden, long term interval electrical stimulation to the motor cortex with a cathodal pulse width of 250's, a frequency of 500Hz, and amplitude of 1.5 times MT may have inhibitory effects on seizures in a rat lithium-pilocarpine model of SE. However, the stimulation with anodal/biphasic pulse and cathodal/anodal DC may not inhibit seizure activity, regardless of length of intervals.
Key Words: Status epilepticus, Electrical stimulation, Motor cortex, Seizure, Lithium-pilocarpine.
TOOLS
METRICS Graph View
  • 1,628 View
  • 3 Download
Related articles


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Neurosurgery, Yonsei University College of Medicine
50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
Tel: +82-2-2228-2150    Fax: +82-2-393-9979    E-mail: changws@yonsei.ac.kr / changws0716@yuhs.ac                

Copyright © 2026 The Korean Society of Stereotactic and Functional Neurosurgery.

Developed in M2PI

Close layer
prev next